AUTOMATED LARGE-VOLUME NUCLEIC ACID EXTRACTION WITH LOW-VOLUME ELUTION
SwiftXtractor™ SL | Compact. Smart. Unique.
Welcome to automation
REDEFINING HIGH-VOLUME EXTRACTION FOR MODERN DIAGNOSTICS
SwiftXtractor™ SL is a compact, automated nucleic acid extraction platform engineered to process large sample input volumes and elute DNA and RNA into low final volumes, all within a single extraction run.
The system enables extraction from 200 µL up to 40 mL of input material, with elution volumes as low as 50 µL, supporting workflows that require increased effective target concentration without additional downstream concentration steps.
Paired with dedicated SwiftX™ Wastewater, SwiftX™ Sepsis, SwiftX™ cfDNA, and other reagent kits, the platform supports end-to-end workflows from sample to molecular analysis.
See complete kit configurations
Input, output volume
FROM UP TO 40 ML IN
DOWN TO 50 µL OUT
The SwiftXtractor™ SL processes sample input volumes ranging from 200 µL up to 40 mL and concentrates purified DNA/RNA into eluates as low as 50 µL, all within a single automated run.
This high input-to-output ratio eliminates the need for manual pre-concentration steps (centrifugation, filtration) and delivers higher effective target concentrations for downstream molecular analysis.
Versatility
FLEXIBLE CONFIGURATIONS FOR EVERY WORKFLOW
The SwiftXtractor™ SL uses standard laboratory plastics that you already stock. Switch between 50 mL and 5 mL tube configurations using a simple metal adapter, no hardware changes required.
The same instrument serves high-volume wastewater surveillance and lower-volume clinical extraction workflows.
Custom-designed rod sleeves feature integrated blades for active mixing, a grooved o-ring seal to retain temperature and control steel-bead transport, and a narrow rounded tip for precise low-volume compatibility.
Each sleeve is individually mounted, allowing single-sample through four-sample batches without wasting consumables.
Key Advantages
EXTRACT MORE. WITH LESS.
Five design principles that set SwiftXtractor™ SL apart from conventional benchtop systems.
LARGE-VOLUME PROCESSING FOR HIGHER SENSITIVITY
Input volumes from 0.2 mL up to 40 mL, enabling detection of low-abundance targets.
ROTATING ROD SLEEVES
Controlled mixing. Solid sample grinding and lysis of gram-positive bacteria and fungi.
FULLY AUTOMATED, HANDS-OFF PURIFICATION
Automation minimizes manual steps and operator variability.
CENTRALIZED AND DECENTRALIZED DEPLOYMENT
Compact. 11 kg. Power banks supported.
COST-EFFICIENT AND CONSUMABLE-AGNOSTIC
No proprietary cartridges. Standard 50, 5 and 2 mL tubes.
VALIDATED, READY-TO-USE METHODS
Pre-loaded, application-specific protocols for immediate use.
Workflow
HOW IT WORKS
From sample to purified nucleic acid in four automated steps.
Applications
VALIDATED EXTRACTION PROTOCOLS
Pre-loaded methods for key diagnostic and surveillance workflows, each paired with dedicated SwiftX™ reagent kits.
Validated applications
Water and wastewater viral and microbial DNA/RNA
For microbiology, viral epidemiology, AMR surveillance, and environmental microbiome characterization. Process up to 40 mL of wastewater, surface water, or drinking water directly — no pre-concentration.
Kits
SwiftX™ DNA Water (SXDW-25, 25 rxns)
SwiftX™ Wastewater (SXWW-96, 96 rxns)
Downstream
qPCR, dPCR, ddPCR, multiplex PCR, NGS, Nanopore
Genomic DNA from Whole Blood
For HLA typing, genetic testing, and DNA profiling. Extract high molecular weight genomic DNA from 200–500 µL whole blood with automated magnetic bead-based purification.
Kit
SwiftX™ Blood Genomic (SXBG-100, 100 rxns)
Downstream
NGS, qPCR, LAMP
Bloodstream Pathogen DNA
For sepsis diagnostics and blood culture-free pathogen detection. Process up to 10 mL whole blood for sensitive recovery of bacterial (Gram+, Gram−), and fungal pathogens DNA from bloodstream infections.
Kit:
SwiftX™ Sepsis (SXFB-20, 20 rxns)
Downstream
qPCR, multiplex PCR panels
STI DNA from Urine
For urogenital pathogen screening. Larger urine input volumes (up to 10 mL) improve sensitivity for low-copy-number targets including Chlamydia trachomatis, Neisseria gonorrhoeae, Mycoplasma genitalium, HSV, and HPV and more.
Kit
SwiftX™ Urine (SXU-20, 20 rxns)
Downstream
qPCR, multiplex PCR
cfDNA from Serum, Plasma and Body Fluids
For liquid biopsy, oncology screening, and prenatal testing. Extract cell-free DNA from variable volumes of serum, plasma and other body fluids with minimal fragmentation.
Kit
SwiftX™ cfDNA (SXCF-50, 50 rxns)
Downstream
ddPCR, targeted panels, NGS
Your Sample. Your Protocol.
Have a unique matrix or target? We develop custom extraction protocols for SwiftXtractor™ SL, tailored to your specific sample type, volume, and downstream workflow requirements.
Let's develop it together.
Interface
MODERN AND USER-FRIENDLY INTERFACE
Program Selection Protocol Editing Real-Time Run Monitoring System Settings & Logs UV Light Decontamination Protocol Sharing & Standardization |
Specifications
SWIFTXTRACTOR™ SL VS. CONVENTIONAL SYSTEMS
Complete technical parameters side by side with conventional extraction platforms.
| Parameter | Conventional Systems | SwiftXtractor™ SL |
|---|---|---|
| EXTRACTION PERFORMANCE | ||
| Purification method | Target-binding (silica/bead) | Reverse purification (impurity-binding) and target-binding |
| Input volume | ≤ 2 mL typical | 200 µL – 40 mL |
| Elution volume | 50–200 µL | Down to 50-300 µL |
| Pre-concentration | Usually required | Reduced / eliminated |
| Samples per run | Varies | 1–4 processed simultaneously |
| Heating | Single zone, limited range | 2 independent zones, 37–125 °C |
| Mixing | Standard agitation | Rotating rod sleeves, 60–3,000 rpm |
| HARDWARE & INTERFACE | ||
| Processing positions | Varies | 5 tube positions (incl. 1 sleeve holding) |
| Interface | Varies | 7″ capacitive touchscreen, Android OS |
| Platform configuration | Typically closed | Open and closed (CE-IVD ready) |
| UV decontamination | Rarely available | Integrated UV light cycle, auto-completion |
| Status monitoring | Basic indicators | Sleeve, drawer & door sensors with pop-up alerts |
| CONSUMABLES & COST | ||
| Cartridges / columns | Required (proprietary) | None |
| Centrifuge | Often required | Not required |
| Tube compatibility | Proprietary cartridges | Standard 50 mL / 5 mL / 2 mL snap-cap |
| DEPLOYMENT | ||
| Dimensions | Large benchtop | 21 × 35 × 36 cm |
| Weight | 15–50+ kg typical | ~15 kg |
| Power | AC only | AC (optional DC 24V, 7,5 A) |
| Deployment settings | Central laboratory | Central + decentralized + field |
| Regulatory | Varies | CE-IVD (soon) |
Performance data available on request
Validated in collaboration with academic and public health partners for wastewater AMR monitoring, bloodstream pathogen detection, and cfDNA recovery. Request recovery rates, Ct value comparisons, and inhibitor removal benchmarks under NDA.
How to order
Configurations
Instrument and accessories
SXT-SL
SwiftXtractor™ SL | Automated large-volume magnetic bead–based nucleic acid extraction platform.
Includes instrument, starter rod sleeve set, tube adapter, and power supply.
Consumables
Standard plastics, no proprietary cartridges or columns required.
Services
Installation, training, and maintenance packages for European customers.
SXT-IP
SwiftXtractor Installation Pack
Includes 1× of each consumable + on-site training (valid for Europe, half day)
1890 €
All prices exclude VAT and logistics. Prices valid for direct orders within Europe. Contact us for distribution partner pricing.
Take the next step
Be among the first to access SwiftXtractor™ SL
Ready to automate your molecular workflow?
Early access opportunities available for reference laboratories, public health institutions and innovation partners.
COLLABORATE WITH US
We invite public health laboratories, reference labs, and academic research programs to co-validate SwiftX™ workflows, whether for regional AMR monitoring, viral surveillance pilots, clinical diagnostics, or grant-funded studies.
FAQ
COMMON QUESTIONS
Is centrifugation required?
No. The SwiftXtractor™ SL workflow is column-free and centrifuge-free. Automated magnetic bead-based capture handles lysis, binding, washing, and elution without any manual centrifugation steps.
What input volumes does the system support?
200 µL to 40 mL in standard operation. The system uses standard 50 mL, 5 mL, and 2 mL tubes — no proprietary cartridges or consumables required.
Can the instrument be used in the field without mains power?
Yes. The SwiftXtractor™ SL is can be battery-operated, enabling deployment in mobile laboratories, field stations, and resource-limited settings without a wall outlet. At ~15 kg, it is easily transportable.
What downstream workflows are compatible?
Eluates are compatible with targeted qPCR, multiplex PCR panels, ddPCR, shotgun metagenomic sequencing, and long-read sequencing (including Oxford Nanopore). No additional cleanup is typically required.
Can the system be used for applications beyond wastewater?
Yes. The SwiftXtractor™ SL platform supports the full range of SwiftX™ reagent kits, including kits for blood genomic DNA, cell-free DNA, sepsis diagnostics, and STD screening from urine. The large-volume capability makes it well-suited to any application where target concentration is low relative to sample volume.